DT 200 Users Manual version 1.E
45
Hardware and Wiring
This section describes installation and wiring information for the interface ports. There
are three bi-directional serial ports and one parallel port with TTL inputs and outputs.
The serial ports are used to interface to a weight indicator, a printer and to a host device
or PC for continuous output. The parallel port is used to interface to parallel printers and
for remote switch input and relay control using the TTL I/O.
Serial Port 1 Connector - TB 3 (Com1) Desktop & Stainless
For RS232 input, set switch SW1 to RS232 position, and for current loop input, set the
switch to CL position. NOTE: Jumper pin 7 CTS to 8 RTS if unit locks up on “Print”.
Serial Port 1 – TB3
Pin #
Signal Name
1 +5V
2 RS232 TXD (transmit data)
3 RS232 RXD (receive data))
4 DTR (220 ohm to +5V)
5 Ground (GND)
6 Current Loop Transmit
7 RS232 CTS (busy)
8 RS232 RTS (request to send)
9 Current Loop Input -
10 Current Loop Input +
Serial Port 2 Connector - TB 5 (Com2) Desktop Model 10809
Motherboard
The Desktop model uses the 10809 version motherboard for RS232 or RS485 input.
Jumper SW2 input jumper to correct setting.
Desktop Model 10809 Board Serial Port 2 – TB5
Pin #
Signal Name
1 +5V
2 RS232 TXD (transmit data)
3 RS232 RXD (receive data)
4 DTR (220 ohm to +5V)
5 Ground (GND)
6 Current Loop Transmit
Port 2 RS485 TB6
3 RS485 Transmit -
4 RS485 Transmit +
5 RS485 Receive -
6 RS485 Receive +
Comentarios a estos manuales