DT 200 Data Terminal Operators Manual
DT 200 Users Manual version 1.E Built In Application Programs 6 Installation and Setup This section provides information about unpacking, insta
DT 200 Users Manual version 1.E Built In Application Programs 7 pin assignments and sample cable drawings. See Set Operation Parameters, and P
DT 200 Users Manual version 1.E Built In Application Programs 8 Using the DT200 The DT200 has 7 function keys located at the bottom of the keyb
DT 200 Users Manual version 1.E Built In Application Programs 9 CLEAR TARE: Press the numeric Zero key. Press the TARE key. The tare weight i
DT 200 Users Manual version 1.E Built In Application Programs 10 Built In Application Programs The following built in programs are available:
DT 200 Users Manual version 1.E Built In Application Programs 11 #1 Fill to Setpoint Press F1 key to enter a setpoint. Place an empty contain
DT 200 Users Manual version 1.E Built In Application Programs 12 # 2 Checkweigh: Under/Between/Over The indicator monitors the scale for activi
DT 200 Users Manual version 1.E Built In Application Programs 13 # 3 Weigh-in / Weigh-out This program uses the ID memory for weigh-in / weigh-
DT 200 Users Manual version 1.E Built In Application Programs 14 REBUILD ID MEMORY: Press the ENTER key when the display prompts, “rebuiLd”. T
DT 200 Users Manual version 1.E Built In Application Programs 15 # 4 Axle Weigh – Short Scale Automatically weigh multiple axles (or containers
Table of Contents Introduction...1 What’s In Ea
DT 200 Users Manual version 1.E Built In Application Programs 16 # 5 Axle Weigh – Long Scale, Unattended Automatically weigh multiple axles (or
DT 200 Users Manual version 1.E Built In Application Programs 17 # 6 ID, Tare, and Total This program uses the ID memory to store tare weights
DT 200 Users Manual version 1.E Built In Application Programs 18 Notes • The ID file maintenance functions are password level 1 protected. If
DT 200 Users Manual version 1.E Set Operation Parameters 19 Set Operation Parameters This section describes the operation parameters of the DT2
DT 200 Users Manual version 1.E Set Operation Parameters 20 Scale Parameters No Parameter Name Default Max Value Pas Field Setting 1
DT 200 Users Manual version 1.E Set Operation Parameters 21 88 Print label 88 30 char 2 89 Print label 89 30 char 2 90 Print lab
DT 200 Users Manual version 1.E Set Operation Parameters 22 Parameter Functions Fn. No Function Name Password Level 59 Display Calibr
DT 200 Users Manual version 1.E Set Operation Parameters 23 Parameter 10. Primary Units Type (1 [lb]) The scale is calibrated in the primary
DT 200 Users Manual version 1.E Set Operation Parameters 24 Parameter 15. Alternate Count-by (5) Enter the alternate units count-by. Seria
DT 200 Users Manual version 1.E Set Operation Parameters 25 Parameter 25 Serial Com. Port 2 Mode (4 [8 data bits, no parity]) Enter the mode
# 4 Axle Weigh – Short Scale ...15 Installation...
DT 200 Users Manual version 1.E Set Operation Parameters 26 2 - CONDEC: <st><polarity><weight><units><mode>>
DT 200 Users Manual version 1.E Set Operation Parameters 27 2 Serial Printer interface. Parameter 30 Auto Print LF after CR (1 [yes]) Some
DT 200 Users Manual version 1.E Set Operation Parameters 28 Enter a 0 to disable TTL remote control. Battery, Watch Dog Timer Parameter 41 Bat
DT 200 Users Manual version 1.E Diagnostic Tests 29 Parameter Functions The parameter functions are used to set parameters that are too complex
DT 200 Users Manual version 1.E Diagnostic Tests 30 Access Parameter Functions Hold the CLEAR key down and press the ENTER key. The numeric di
DT 200 Users Manual version 1.E Diagnostic Tests 31 Function 64 Configure Passwords Use function 64 to enter password data. The DT200 provides
DT 200 Users Manual version 1.E Diagnostic Tests 32 DEFAULT PRINT FORMATS. The print formats (PAGES) are initialized to factory settings when
DT 200 Users Manual version 1.E Diagnostic Tests 33 Page List FORMAT DESCRIPTION PAGE 1 Prints when the DT200 is in the GROSS weight mode.
DT 200 Users Manual version 1.E Diagnostic Tests 34 Print Format Design Example EXAMPLE PRINT: EXAMPLE FORMAT DESIGN WORKSHEET: Page:1
DT 200 Users Manual version 1.E Diagnostic Tests 35 Format Design Worksheets Page Item Description Line No. Column Item No. E1
Function 68 Print Operation Parameters ...36 Function 69 Diagnostic Test
DT 200 Users Manual version 1.E Diagnostic Tests 36 Function 66 Set Time and Date Use function 66 to set the time and date. Entering 19 can di
DT 200 Users Manual version 1.E Diagnostic Tests 37 12 Serial Com. Port 1 Transmit/Receive loop-back test. 13 Serial Com. Port 2 Trans
DT 200 Users Manual version 1.E Diagnostic Tests 38 4. Use the UNITS key (↓) or the PRINT key (↑) to scroll through the entry numbers. Press
DT 200 Users Manual version 1.E Diagnostic Tests 39 Parameter 91 Serial Port 3 Mode (4 [8 data bits, no parity]) Enter the mode number from t
DT 200 Users Manual version 1.E Diagnostic Tests 40 Diagnostic Tests The DIAGNOSTIC TESTS are accessed using configuration function 69. Hold t
DT 200 Users Manual version 1.E Diagnostic Tests 41 Diagnostic Test 2: Serial Com Port 1 - Display Errors Diagnostic Test 5: Serial Com Por
DT 200 Users Manual version 1.E 42 Troubleshooting The following table describes the probable causes to some problems you may encounter. Most
DT 200 Users Manual version 1.E 43
DT 200 Users Manual version 1.E 44 Error Messages Error Description Err 0 Power on zero error. See parameter 20. Err 1 Keyboard error
DT 200 Users Manual version 1.E 45 Hardware and Wiring This section describes installation and wiring information for the interface ports. T
DT 200 Users Manual version 1.E Introduction 1 Introduction Congratulations on your purchase and welcome to the DT200 User's Manual. This manu
DT 200 Users Manual version 1.E 46 Stainless Steel Wall Mount or Panel mount Serial Port 2 Connector - TB 5
DT 200 Users Manual version 1.E 47 Stainless Steel Wall Mount or Panel Mount Serial Port 3 RS485/TTL Connector - TB 6 For RS232 or RS485, jump
DT 200 Users Manual version 1.E 48 P.C. Board Diagram - Connectors, Jumpers, and Switches 7 6 5 4 3 2 1 CurLoop SW4 RS232
DT 200 Users Manual version 1.E 49 Sample Cable Drawings IDS150A/152/160/320 DT210/IDS550/IDS710/PC (Continuous Output Port) DB 25 PIN M
DT 200 Users Manual version 1.E 50 DB 25 PIN MALE (20ma Current Loop) TB5 Serial Com Port 2 +5V CL2 TX 1 7 22 CL+ CL- DT210 / IDS550 / I
DT 200 Users Manual version 1.E 51 Parallel (Centronix) Printer Remote Switch Inputs GND 4 5 6 7 3 TB 4 TTL Inputs Scale Basic Funct
DT 200 Users Manual version 1.E 52
DT 200 Users Manual version 1.E 53 DT200 Specifications Display Vacuum Florescent 8-digit numeric with 6 status indicators. Keyboard S
DT 200 Users Manual version 1.E 54 ASCII CHART ASCII DEC ASCII DEC ASCII DEC ASCII DEC Null 00 SP 32
DT 200 Users Manual version 1.E Introduction 2 Scale Basic / Event Monitor Programming The DT200 offers "Scale Basic" programming capabil
DT 200 Users Manual version 1.E Introduction 3 WARRANTY INFORMATION INDUSTRIAL DATA SYSTEMS, INC. LIMITED WARRANTY. Industrial Data Systems, Inc.,
DT 200 Users Manual version 1.c General Description 4 General Description This section gives you a general description on the operation of the
DT 200 Users Manual version 1.c General Description 5 MOTION- The weight on the scale is changing (not stable). ZERO- The scale is at &q
Comentarios a estos manuales